- 0,25 vol.% CO + 3,0 vol.% CO2 + 80 vol.ppm C3H8 in N2
Vehicle Exhaust Test Gas - Mixture LVery close1 week(s)
10L 150 bar 1,5 m³Calibration certificate (ISO 17025) Calibration certificate (ISO 17025)Purity: CO N47, CO2 N55, C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 0,5 vol.% CO + 6,0 vol.% CO2 + 200 vol.ppm C3H8+ 0,5 vol.% O2 in N2
Vehicle Exhaust Test Gas - Mixture EVery close1 week(s)
10L 150 bar 1,5 m³Calibration certificate (ISO 17025) Calibration certificate (ISO 17025)Purity: CO N47, CO2 N55, C3H8 N35, O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 1 vol.% CO + 10 vol.% CO2 + 600 vol.ppm C3H8+ 10 vol.% O2 in N2
Vehicle Exhaust Test Gas - Mixture FVery close1 week(s)
10L 150 bar 1,5 m³Calibration certificate (ISO 17025) Calibration certificate (ISO 17025)Purity: CO N47, CO2 N45, C3H8 N35, O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 3,5 vol.% CO + 14,0 vol.% CO2 + 0,2 vol.% C3H8 in N2
Vehicle Exhaust Test Gas - Mixture DVery close1 week(s)
10L 150 bar 1,5 m³Calibration certificate (ISO 17025) Calibration certificate (ISO 17025)Purity: CO N47, CO2 N55, C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 3,5 vol.% CO + 14,0 vol.% CO2 + 0,2 vol.% C3H8 + 20,9 vol.% O2 in N2
Vehicle Exhaust Test Gas - Mixture GVery close1 week(s)
10L 150 bar 1,5 m³Calibration certificate (ISO 17025) Calibration certificate (ISO 17025)Purity: CO N47, CO2 N55, C3H8 N35, O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 5 vol.% CO + 14,0 vol.% CO2 + 0,2 vol.% C3H8 + 20,9 vol.% O2 in N2
Vehicle Exhaust Test Gas - Mixture HVery close1 week(s)
10L 150 bar 1,5 m³Calibration certificate (ISO 17025) Calibration certificate (ISO 17025)Purity: CO N47, CO2 N55, C3H8 N35, O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - Purity: N2 N60, N2Stability: 36 monthsConnection: B4 (BELUX) or RU-3 (NL)
- 0,29 vol.% O2 in N2
Vehicle Exhaust Test Gas - ZeroVery close1 week(s)
10L 150 bar 1,5 m³Calibration certificate (ISO 17025) Calibration certificate (ISO 17025)Purity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 22,5 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 22,5 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 45 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 45 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 90 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 90 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 225 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 225 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 450 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 450 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 900 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 900 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 2250 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 2250 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 4750 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 4750 ppm-mol CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 4,5 mol.% CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 4,5 mol.% CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 9,9 mol.% CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 9,9 mol.% CO in N2
Mixture - Carbon Monoxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO N47, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 2,25 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N48, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 2,25 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N48, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 4,5 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 4,5 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 5 vol.% CO2 + 10 vol.% H2 in N2
Process Gas Mixture CO2/H2/N2 5/10/85Very close2 week(s)
10L 150 bar 1,5 m³Purity: CO2 N45, H2 N30, N2Stability: 36 monthsConnection: B8 (BELUX) or DIN 1 (NL) - 9,9 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N48, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 9,9 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,95 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N48, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 10 vol.% CO2 in N2
High-Gas Mixture Carbon Dioxide in NitrogenVery close2 week(s)
10L 150 bar 1,5 m³Purity: CO2 N45, N2Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 10 vol.% CO2 + 5 vol.% H2 in N2
Process Gas Mixture CO2/H2/N2 10/5/85Very close2 week(s)
10L 150 bar 1,5 m³Purity: CO2 N45, H2 N50, N2Stability: 36 monthsConnection: B8 (BELUX) or DIN 1 (NL) - 5 vol.% CO2 + 5 vol.% H2 in N2
Process Gas Mixture CO2/H2/N2 5/5/90Very close2 week(s)
10L 150 bar 1,5 m³Purity: CO2 N45, H2 N50, N2Stability: 36 monthsConnection: B8 (BELUX) or DIN 1 (NL) - 10 vol.% CO2 in N2
HIgh-Gas Mixture - Carbon Dioxide in NitrogenVery close2 week(s)
10L 200 bar 2 m³Purity: CO2 N45, N2Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 15 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N48, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 15 mol.% CO2 in N2
Mixture - Carbon Dioxide in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 2 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: CO2 N48, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - Purity: H2 N30, N2Blending tolerance: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 1 (NL)
- 1,9 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 1,9 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 4,7 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 4,7 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 10 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 10 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 20,8 mol.% O2 in N2
Alphagaz Auto AirVery close2 week(s)
10L 200 bar 2 m³With product tagPurity: O2 N55, N2Blending tolerance: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or RU-6 (NL) - 22 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 150 bar 1,43 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 22 mol.% O2 in N2
Mixture - Oxygene in Nitrogen - 1% AccuracyVery close2 week(s)
10L 200 bar 1,9 m³Certificate of analysis (ISO 6141) traceable to reference material of VSLPurity: O2 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 1 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 30 vol ppm R114 in N2
Test gas - Halocarbon 114 in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2Cl2F4 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 100 vol ppm R113 in N2
Test gas - Halocarbon 113 in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2Cl3F3 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - (50% LEL) 1,25 vol % C2H2 in Air
Test gas - 50% LEL Acetylene in AirVery close3 week(s)
10L 120 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2H2 N25, N2Blending tolerance: +/- 20 % rel.Analytical accuracy: +/- 10 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 30 vol ppm R134a in N2
Test gas - Halocarbon 134a in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2H2F4 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 100 vol ppm R134a in N2
Test gas - Halocarbon 134a in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2H2F4 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - (43% LEL) 1,16 Vol % C2H4 in Air
Test gas - 43% LEL Ethylene in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2H4 N40, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (50% LEL) 1,35 Vol % C2H4 in Air
Test gas - 50% LEL Ethylene in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2H4 N40, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (50% LEL) 1,5 Vol % C2H6 in Air
Test gas - 50% LEL Ethane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2H6 N40, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 30 vol ppm R123 in N2
Test gas - Halocarbon 123 in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2HCl2F3 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 50 vol ppm R123 in N2
Test gas - Halocarbon 123 in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2HCl2F3 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 100 vol ppm R123 in N2
Test gas - Halocarbon 123 in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C2HCl2F3 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - (50% LEL) 2 vol % H2 in Air
Test gas - 50% LEL Hydrogen in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 1000 vol ppm C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (10 % LEL) 0,21 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (20 % LEL) 0,42 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (25 % LEL) 0,53 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (26 % LEL) 0,55 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 0,57 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (30 % LEL) 0,63 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (35 % LEL) 0,74 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (45 % LEL) 0,95 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 120 bar 1,2 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (50 % LEL) 1 vol % C3H6 in Air
Test gas - Propylene in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (50 % LEL) 1,05 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 110 bar 1,1 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (25 % LEL) 1,43 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 42 bar 0,42 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 1,5 vol % C3H8 in Air
Test gas - Propane in AirVery close3 week(s)
10L 42 bar 0,42 m³Certificate of analysis (ISO 6141)Purity: C3H8 N35, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 0,14 vol % n-C5H12 in Air
Test gas - n-Pentane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C5H12 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 0,17 vol % n-C5H12 in Air
Test gas - n-Pentane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C5H12 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (25 % LEL) 0,35 vol % n-C5H12 in Air
Test gas - n-Pentane in AirVery close3 week(s)
10L 125 bar 1,25 m³Certificate of analysis (ISO 6141)Purity: C5H12 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 0,39 vol % n-C5H12 in Air
Test gas - n-Pentane in AirVery close3 week(s)
10L 110 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C5H12 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (50 % LEL) 0,7 vol % n-C5H12 in Air
Test gas - n-Pentane in AirVery close3 week(s)
10L 62 bar 0,62 m³Certificate of analysis (ISO 6141)Purity: C5H12 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (45 % LEL) 0,76 vol % n-C5H12 in Air
Test gas - n-Pentane in AirVery close3 week(s)
10L 34 bar 0,34 m³Certificate of analysis (ISO 6141)Purity: C5H12 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 50 vol ppm iso-C4H8 in Air
Test gas - Isobutylene in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C5H12 N20, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 400 vol ppm n-C6H14 in Air
Test gas - n-Hexane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C6H14 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 500 vol ppm n-C6H14 in Air
Test gas - n-Hexane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C6H14 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (25% LEL) 0,3 vol % n-C6H14 in Air
Test gas - n-Hexane in AirVery close3 week(s)
10L 13 bar 0,13 m³Certificate of analysis (ISO 6141)Purity: C6H14 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - (40% LEL) 0,48 vol % n-C6H14 in Air
Test gas - n-Hexane in AirVery close3 week(s)
10L 7,2 bar 0,07 m³Certificate of analysis (ISO 6141)Purity: C6H14 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 5 vol ppm C6H6 in Air
Test gas - Benzene in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C6H6 N25, N2Blending tolerance: +/- 20 % rel.Analytical accuracy: +/- 10 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 100 vol ppm C6H6 in Air
Test gas - Benzene in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: C6H6 N25, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 800 vol ppm n-C7H16 in Air
Test gas - n-Heptane in AirVery close3 week(s)
10L 13 bar 0,13 m³Certificate of analysis (ISO 6141)Purity: C7H16 N20, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 100 vol ppm C7H8 in N2
Test gas - Toluene in N2Very close3 week(s)
10L 117 bar 1,17 m³Certificate of analysis (ISO 6141)Purity: C7H8 N20, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 5 (NL) - 100 vol ppm R12 in N2
Test gas - Halocarbon 12 in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CCl2F2 N30, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 2000 vol ppm R12 in Air
Test gas - Halocarbon 12 in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CCl2F2 N30, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 100 vol ppm R11 in N2
Test gas - Halocarbon 11 in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CCl3F N30, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B4 (BELUX) or DIN 6 (NL) - 200 vol ppm R40 in Air
Test gas - Methyl Chloride (R40) in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CH3Cl N30, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 300 vol ppm R40 in Air
Test gas - Methyl Chloride (R40) in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CH3Cl N30, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 10 vol ppm CH4 in N2
Test gas - Methane in N2Very close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CH4 N45, N2Blending tolerance: +/- 20 % rel.Analytical accuracy: +/- 10 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 1 (NL) - 50 vol ppm CH4 in Air
Test gas - Methane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CH4 N45, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 100 vol ppm CH4 in Air
Test gas - Methane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CH4 N45, N2Blending tolerance: +/- 10 % rel.Analytical accuracy: +/- 5 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL) - 500 vol ppm CH4 in Air
Test gas - Methane in AirVery close3 week(s)
10L 150 bar 1,5 m³Certificate of analysis (ISO 6141)Purity: CH4 N45, N2Blending tolerance: +/- 5 % rel.Analytical accuracy: +/- 2 % rel.Stability: 36 monthsConnection: B8 (BELUX) or DIN 14 (NL)