Air Liquide Mixture Guide

  • (30 % LEL) 1,5 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • (40 % LEL) 2 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 2 vol % CH4 in N2
    Test gas - Methane in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 2 vol % CH4 in N2
    Test gas - Methane in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • (50 % LEL) 2,5 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • (50 % LEL) 2,5 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • (60 % LEL) 3 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    5L 97 bar 0,49 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • (60 % LEL) 3 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    50L 97 bar 4,85 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • (65 % LEL) 3,25 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    5L 80 bar 0,4 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • (65 % LEL) 3,25 vol % CH4 in Air
    Test gas - Methane in Air
    Very close
    3 week(s)
    50L 80 bar 4 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 5 vol.% CH4 in Ar
    Argon/Methane 95/5 - ECD Mixture
    Very close
    3 week(s)
    50L 200 bar 10,7 m³
    Add to Quote
    Purity: CH4 N25, Ar
    Blending tolerance: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 5 vol.% CH4 in Ar
    Argon/Methane 95/5 - Nuclear Counter Mixture
    Very close
    3 week(s)
    50L 200 bar 10,7 m³
    Add to Quote
    Purity: CH4 N25, Ar
    Blending tolerance: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 10 vol.% CH4 in Ar
    Argon/Methane 90/10 - Nuclear Counter Mixture
    Very close
    3 week(s)
    50L 200 bar 10,7 m³
    Add to Quote
    Purity: CH4 N25, Ar
    Blending tolerance: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 10 vol.% CH4 in Ar
    Alphagaz Mix 10% CH4 in Argon
    Very close
    3 week(s)
    50L 200 bar 10,8 m³
    Add to Quote
    Purity: CH4 N25, Ar
    Blending tolerance: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 10 vol.% CH4 in Ar
    Argon/Methane 90/10 - ECD Mixture
    Very close
    3 week(s)
    50L 200 bar 10,8 m³
    Add to Quote
    Purity: CH4 N25, Ar
    Blending tolerance: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 10 vol % CH4 in N2
    Test gas - Methane in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 10 vol % CH4 in N2
    Test gas - Methane in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 17 vol.% CH4 + 24 vol.% N2 in H2
    Burner calibration gas G112
    Very close
    3 week(s)
    50L 150 bar 7,1 m³
    Add to Quote
    Purity: CH4 N25, N2 N50, H2
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 50 vol % CH4 in N2
    Test gas - Methane in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 1 (NL)
  • 10 vol ppm R22 in N2
    Test gas - Halocarbon 22 in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 10 vol ppm R22 in N2
    Test gas - Halocarbon 22 in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 100 vol ppm R22 in Air
    Test gas - Halocarbon 22 in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 100 vol ppm R22 in N2
    Test gas - Halocarbon 22 in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 100 vol ppm R22 in N2
    Test gas - Halocarbon 22 in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 100 vol ppm R22 in Air
    Test gas - Halocarbon 22 in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 100 vol ppm R22 in N2
    Test gas - Halocarbon 22 in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 100 vol ppm R22 in N2
    Test gas - Halocarbon 22 in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2000 vol ppm R22 in Air
    Test gas - Halocarbon 22 in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2000 vol ppm R22 in Air
    Test gas - Halocarbon 22 in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CHClF2 N30, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 10 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 10 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 10 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 20 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 20 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 25 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 25 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 35 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 35 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 40 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 40 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 50 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 50 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 50 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 50 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 60 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 60 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 95 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 95 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 100 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 100 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 100 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 100 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 150 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 150 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 200 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 200 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 200 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 200 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 250 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 250 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 300 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 300 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 400 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 400 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 500 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 500 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 1000 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 1000 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 1000 vol ppm CO in N2
    Test gas - Carbon Monoxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 20 % rel.
    Analytical accuracy: +/- 10 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 5 (NL)
  • 1000 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 5000 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 5000 vol ppm CO in Air
    Test gas - Carbon Monoxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO N47, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 100 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 100 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 300 vol ppm CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 300 vol ppm CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 10 % rel.
    Analytical accuracy: +/- 5 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 400 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 400 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 500 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 500 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 800 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 800 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 1000 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 1000 vol ppm CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 1000 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 1000 vol ppm CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2000 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2000 vol ppm CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2000 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2000 vol ppm CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 5000 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 5000 vol ppm CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 1 vol % CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 1 vol % CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2,5 vol % CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2,5 vol % CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    5L 150 bar 0,75 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2,5 vol % CO2 in N2
    Test gas - Carbon Dioxide in N2
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 2,5 vol % CO2 in Air
    Test gas - Carbon Dioxide in Air
    Very close
    3 week(s)
    50L 150 bar 7,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 2 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 5 vol.% CO2 in O2
    Carbogen CO2 5%/O2
    Very close
    3 week(s)
    50L 150 bar 8,2 m³
    Add to Quote
    Purity: CO2 N45, O2
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
  • 10 vol.% CO2 in Ar
    Argon/Carbon Dioxide 90/10
    Very close
    3 week(s)
    50L 200 bar 11 m³
    Add to Quote
    Purity: CO2 N45, Ar
    Blending tolerance: +/- 10 % rel.
    Stability: 12 months
    Connection: B4 (BELUX) or DIN 6 (NL)
Processing - Please wait...