Air Liquide Mixture Guide

  • 9,75 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 22,5 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 22,5 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 22,5 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 45 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 45 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 45 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 97,5 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 97,5 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 97,5 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 450 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 450 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 450 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 975 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 975 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 975 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 2250 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 2250 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 2250 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 3750 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 3750 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 3750 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 9750 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    5L 150 bar 0,68 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 9750 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 150 bar 7,2 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 9750 ppm-mol NO in N2
    Mixture - Nitric Oxide in Nitrogen - 1% Accuracy
    Very close
    5 week(s)
    50L 200 bar 9,6 m³
    Certificate of analysis (ISO 6141) traceable to reference material of VSL
    Add to Quote
    Purity: NO N25, N2
    Blending tolerance: +/- 5 % rel.
    Analytical accuracy: +/- 1 % rel.
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 8 (NL)
  • 0,4 mol.% O2 + 4,0 mol.% N2 + 2,5 mol.% CO2 + 0,2 mol.% H2 + 2,5 mol.% C2H6 + 1,0 mol.% C3H8 + 0,2 mol.% n−C4H10 + 0,2 mol.% i−C4H10 in CH4
    GC gas / 9 components - CH4 / 91,3% (+H2/O2)
    Very close
    5 week(s)
    5L 150 bar 0,95 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: O2 N45, N2 N50, CO2 N55, H2 N30, C2H6 N35, C3H8 N35, C4H10 N35, i-C4H10 N35, CH4
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 0,4 mol.% O2 + 4,0 mol.% N2 + 2,5 mol.% CO2 + 0,2 mol.% H2 + 2,5 mol.% C2H6 + 1,0 mol.% C3H8 + 0,2 mol.% n−C4H10 + 0,2 mol.% i−C4H10 in CH4
    GC gas / 9 components - CH4 / 91,3% (+H2/O2)
    Very close
    5 week(s)
    50L 150 bar 9,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: O2 N45, N2 N50, CO2 N55, H2 N30, C2H6 N35, C3H8 N35, C4H10 N35, i-C4H10 N35, CH4
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 0,5 mol.% O2 + 4,0 mol.% N2 + 1,5 mol.% CO2 + 4,0 mol.% C2H6 + 1,0 mol.% C3H8 + 0,2 mol.% n−C4H10 + 0,2 mol.% i−C4H10 + 0,05 mol.% n−C5H12 + 0,05 mol.% i−C5H12 + 0,05 mol.% C6H14 in CH4
    GC gas / 11 components - CH4 / 88,45% (+O2)
    Very close
    5 week(s)
    5L 150 bar 0,95 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: See PDS
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 0,5 mol.% O2 + 4,0 mol.% N2 + 1,5 mol.% CO2 + 4,0 mol.% C2H6 + 1,0 mol.% C3H8 + 0,2 mol.% n−C4H10 + 0,2 mol.% i−C4H10 + 0,05 mol.% n−C5H12 + 0,05 mol.% i−C5H12 + 0,05 mol.% C6H14 in CH4
    GC gas / 11 components - CH4 / 88,45% (+O2)
    Very close
    5 week(s)
    50L 150 bar 9,5 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: See PDS
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 2,0 mol.% O2 + 8,0 mol.% N2 + 2,0 mol.% CO2 + 1,0 mol.% H2 + 4,0 mol.% C2H6 + 3,0 mol.% C3H8 + 0,5 mol.% n−C4H10 + 0,5 mol.% i−C4H10 in CH4
    GC gas / 9 components - CH4 / 80,8% (+H2/O2)
    Very close
    5 week(s)
    5L 100 bar 0,6 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: O2 N45, N2 N50, CO2 N55, H2 N30, C2H6 N35, C3H8 N35, C4H10 N35, i-C4H10 N35, CH4
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 2,0 mol.% O2 + 8,0 mol.% N2 + 2,0 mol.% CO2 + 1,0 mol.% H2 + 4,0 mol.% C2H6 + 3,0 mol.% C3H8 + 0,5 mol.% n−C4H10 + 0,5 mol.% i−C4H10 in CH4
    GC gas / 9 components - CH4 / 80,8% (+H2/O2)
    Very close
    5 week(s)
    50L 100 bar 6 m³
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: O2 N45, N2 N50, CO2 N55, H2 N30, C2H6 N35, C3H8 N35, C4H10 N35, i-C4H10 N35, CH4
    Stability: 36 months
    Connection: B8 (BELUX) or DIN 14 (NL)
  • 5 mol ppb Ethane in Air
    IsoTop Gas Mixture - Ethane (ppb) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: C2H6 N40, Air
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 100 mol ppb Ethane in Air
    IsoTop Gas Mixture - Ethane (ppb) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: C2H6 N40, Air
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1000 mol ppb Ethane in Air
    IsoTop Gas Mixture - Ethane (ppb) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: C2H6 N40, Air
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 2 mol ppm CH4 in Air with δ13C= -69 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -69 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 2 mol ppm CH4 in Air with δ13C= -45 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -45 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 2 mol ppm CH4 in Air with δ13C= -25 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -25 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 10 mol ppm CH4 in Air with δ13= -69 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -69 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 10 mol ppm CH4 in Air with δ13C= -45 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -45 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 10 mol ppm CH4 in Air with δ13C= -25 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -25 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 30 mol ppm CH4 in Air with δ13C= -69 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -69 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 30 mol ppm CH4 in Air with δ13C= -45 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -45 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 30 mol ppm CH4 in Air with δ13C= -25 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -25 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 500 mol ppm CH4 in Air with δ13C= -69 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -69 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 500 mol ppm CH4 in Air with δ13C= -45 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -45 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 500 mol ppm CH4 in Air with δ13C= -25 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -25 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1000 mol ppm CH4 in Air with δ13C= -69 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -69 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1000 mol ppm CH4 in Air with δ13C= -45 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -45 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1000 mol ppm CH4 in Air with δ13C= -25 ‰ vs VPDB
    IsoTop Gas Mixture - CH4 in Air (δ13C= -25 ‰ +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 250 mol ppm CO2 (δ13C= -5 ‰ vs VDPB) and 1 mol ppm CH4 (δ13C= -25 ‰ vs VPDB) in Air
    Low - CO2 (δ13C= -5 ‰ +/-0,3) and CH4 (δ13C= -25 ‰ +/-0,5) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, CH4 N45, Air
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 300 mol ppm CO2 in Air with δ13C= -40 ‰ vs VPDB
    IsoTop Gas Mixture - CO2 in Air (δ13C= -40 ‰ +/-0,3)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 300 mol ppm CO2 in Air with δ13C= -25 ‰ vs VPDB
    IsoTop Gas Mixture - CO2 in Air (δ13C= -25 ‰ +/-0,3)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 300 mol ppm CO2 in Air with δ13C= -5 ‰ vs VPDB
    IsoTop Gas Mixture - CO2 in Air (δ13C= -5 ‰ +/-0,3)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 350 mol ppm CO2 (δ13C= -10 ‰ vs VDPB) and 2 mol ppm CH4 (δ13C= -45 ‰ vs VPDB) in Air
    Medium - CO2 (δ13C= -10 ‰ +/-0,3) and CH4 (δ13C= -45 ‰ +/-0,5) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, CH4 N45, Air
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 400 mol ppm CO2 (δ13C= -8,6 ‰ vs VDPB) and 1,8 mol ppm CH4 (δ13C= -47 ‰ vs VPDB) in Air
    Natural - CO2 (δ13C= -8,6 ‰ +/-0,3) and CH4 (δ13C= -47 ‰ +/-0,5) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, CH4 N45, Air
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1000 mol ppm CO2 (δ13C=-20 ‰ vs VDPB) and 10 mol ppm CH4 (δ13C= -69 ‰ vs VPDB) in Air
    High - CO2 (δ13C= -20 ‰ +/-0,3) and CH4 (δ13C= -69 ‰ +/-0,5) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1000 mol ppm CO2 (δ13C= -30 ‰ vs VDPB) and 1000 mol ppm CH4 (δ13C= -25 ‰ vs VPDB) in Air
    High-High - CO2 (δ13C= -30 ‰ +/-0,3) and CH4 (δ13C= -25 ‰ +/-0,5) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1500 mol ppm CO2 in Air with δ13C= -40 ‰ vs VPDB
    IsoTop Gas Mixture - CO2 in Air (δ13C= -40 ‰ +/-0,3)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1500 mol ppm CO2 in Air with δ13C= -5 ‰ vs VPDB
    IsoTop Gas Mixture - CO2 in Air (δ13C= -5 ‰ +/-0,3)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1500 mol ppm CO2 in Air with δ13C= -25 ‰ vs VPDB
    IsoTop Gas Mixture - CO2 in Air (δ13C= -25 ‰ +/-0,3)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 2500 mol ppm CO2 (δ13C= -50 ‰ vs VDPB) and 100 mol ppm CH4 (δ13C= -55 ‰ vs VPDB) in Air
    Depleted - CO2 (δ13C= -50 ‰ +/-0,3) and CH4 (δ13C= -55 ‰ +/-0,5) in Air
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: CO2 N55, CH4 N45, Air
    Analytical accuracy: +/- 2 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 300 mol ppb N2O (δ15N= 2,2 ‰ + δ15Nα= 3,2 ‰ + δ15Nβ= 1,2 ‰ vs atm N2) and 20,9 mol % O2 (δ18O= 39,3 ‰ vs VSMOW) in N2
    δ / N2O + O2 (δ15N+δ15Nα +/-0,5 + δ15Nβ +/-1 and δ18O +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: N2O N30, O2 N45, N2
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 300 mol ppb N2O (δ15N= -0,3 ‰ + δ15Nα= -0,4 ‰ + δ15Nβ= -0,2 ‰ vs atm N2) and 20,9 mol % O2 (δ18O= 41,9 ‰ vs VSMOW) in N2
    δ / N2O + O2 (δ15N+δ15Nα +/-0,5 + δ15Nβ +/-1 and δ18O +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: N2O N30, O2 N45, N2
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1500 mol ppb N2O (δ15N= 2,2 ‰ + δ15Nα= 3,2 ‰ + δ15Nβ= 1,2 ‰ vs atm N2) and 20,9 mol % O2 (δ18O= 39,3 ‰ vs VSMOW) in N2
    δ / N2O + O2 (δ15N+δ15Nα +/-0,5 + δ15Nβ +/-1 and δ18O +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: N2O N30, O2 N45, N2
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
  • 1500 mol ppb N2O (δ15N= -0,3 ‰ + δ15Nα= -0,4 ‰ + δ15Nβ= -0,2 ‰ vs atm N2) and 20.9 mol % O2 (δ18O= 41,9 ‰ vs VSMOW) in N2
    δ / N2O + O2 (δ15N+δ15Nα +/-0,5 + δ15Nβ +/-1 and δ18O +/-1)
    Very close
    6 week(s)
    34DAL 34 bar 34 liters (gas)
    Certificate of analysis (ISO 6141)
    Add to Quote
    Purity: N2O N30, O2 N45, N2
    Analytical accuracy: +/- 10 % rel.
    Stability: 36 months
    Connection: C-10 (5/8"-18 UNF standard) (BELUX) or C-10 (5/8"-18 UNF standard) (NL)
Processing - Please wait...